JEE MAIN 2026 · 23 JAN S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Given below are two statements: one is labelled as Assertion (A) and the other is labelled as Reason (R)
Consider a ferromagnetic material :
Assertion (A) : The individual atoms in a ferromagnetic material possess a magnetic dipole moment and interact with one another in such a way that they spontaneously align themselves forming domains.
Reason (R): At high enough temperature, the domain structure of ferromagnetic material disintegrates. Thus, magnetization will disappear at high enough temperature known as Curie temperature.
In the light of the above statements, choose the correct answer from the options given below :
- A
Both (A) and (R) are true but (R) is not the correct explanation of (A)
- B
(A) is true but (R) is false
- C
Both (A) and (R) are true and (R) is the correct explanation of (A)
- D
(A) is false but (R) is true
JEE MAIN 2026 · 04 APR S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
A solenoid has a core made of material with relative permeability 400. The magnetic field produced in the interior of solenoid is 1.0 T. The magnetic intensity in SI units is α×105. The value of α is ______.
(Free space permeability μ0=4π×10−7 SI units.)
- A
- B
- C
- D
JEE MAIN 2025 · 07 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The percentage increase in magnetic field (B) when space within a current carrying solenoid is filled with magnesium (magnetic susceptibility χmg=1.2×10−5) is :
- A
56×10−3%
- B
65×10−5%
- C
65×10−4%
- D
35×10−5%
JEE MAIN 2025 · 02 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The relationship between the magnetic susceptibility (χ) and the magnetic permeability (μ) is given by: (μ0 is the permeability of free space and μr is relative permeability)
- A
χ=μ0μ−1
- B
χ=μ0μr+1
- C
χ=μr+1
- D
χ=1−μ0μ
JEE MAIN 2024 · 06 APR S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Match List-I with List-II :
Choose the correct answer from the options given below :
- A
(A)-(IV), (B)-(I), (C)-(III), (D)-(II)
- B
(A)-(I), (B)-(III), (C)-(II), (D)-(IV)
- C
(A)-(III), (B)-(IV), (C)-(I), (D)-(II)
- D
(A)-(III), (B)-(I), (C)-(IV), (D)-(II)
JEE MAIN 2024 · 08 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Paramagnetic substances:
A. align themselves along the directions of external magnetic field.
B. attract strongly towards external magnetic field.
C. has susceptibility little more than zero.
D. move from a region of strong magnetic field to weak magnetic field.
Choose the most appropriate answer from the options given below:
- A
- B
- C
- D
JEE MAIN 2024 · 08 APR S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The coercivity of a magnet is 5×103 A/m. The amount of current required to be passed in a solenoid of length 30 cm and the number of turns 150, so that the magnet gets demagnetised when inside the solenoid is _____ A.
JEE MAIN 2023 · 12 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Given below are two statements:
Statement I : The diamagnetic property depends on temperature.
Statement II : The induced magnetic dipole moment in a diamagnetic sample is always opposite to the magnetising field.
In the light of statements, choose the correct answer from the options given below
- A
Both Statement I and Statement II are False
- B
Statement I is incorrect but Statement II is true
- C
Statement I is correct but Statement II is false
- D
Both Statement I and Statement II are true
JEE MAIN 2023 · 25 JAN S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
A solenoid of 1200 turns is wound uniformly in a single layer on a glass tube 2 m long and 0.2 m in diameter. The magnetic intensity at the center of the solenoid when a current of 2 A flows through it is:
- A
2.4×103 A m−1
- B
1.2×103 A m−1
- C
- D
2.4×10−3 A m−1
JEE MAIN 2023 · 08 APR S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Given below are two statements: one is labelled as Assertion A and the other is labelled as Reason R.
Assertion A: Electromagnets are made of soft iron.
Reason R: Soft iron has high permeability and low retentivity.
In the light of above statements, choose the most appropriate answer from the options given below.
- A
A is not correct but R is correct
- B
A is correct but R is not correct
- C
Both A and R are correct and R is the correct explanation of A
- D
Both A and R are correct but R is NOT the correct explanation of A
JEE MAIN 2023 · 10 APR S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Given below are two statements:
Statement I: For diamagnetic substance −1≤x<0, where x is the magnetic susceptibility.
Statement II: Diamagnetic substance when placed in an external magnetic field, tend to move from stronger to weaker part of the field. In the light of the above statements, choose the correct answer from the options give below.
- A
Both Statement I and Statement II are False
- B
Statement I is correct but Statement II is false
- C
Statement I is incorrect but Statement II is true
- D
Both Statement I and Statement II are true
JEE MAIN 2023 · 31 JAN S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
A rod with circular cross-section area 2 cm2 and length 40 cm is wound uniformly with 400 turns of an insulated wire. If a current of 0.4 A flows in the wire windings, the total magnetic flux produced inside the windings is 4π×10−6 Wb. The relative permeability of the rod is
(Given: Permeability of vacuum μ0=4π×10−7 N A−2)
- A
- B
- C
- D
JEE MAIN 2023 · 11 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The free space inside a current carrying toroid is filled with a material of susceptibility 2×10−2. The percentage increase in the value of magnetic field inside the toroid will be
- A
- B
- C
- D
JEE MAIN 2023 · 10 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The current required to be passed through a solenoid of 15 cm length and 60 turns in order to demagnetise a bar magnet of magnetic intensity 2.4×103 A m−1 is _______ A.
JEE MAIN 2023 · 08 APR S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The magnetic intensity at the centre of a long current carrying solenoid is found to be 1.6×103 A m−1. If the number of turns is 8 per cm, then the current flowing through the solenoid is ______ A.
JEE MAIN 2022 · 25 JUN S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
Given below are two statements :
Statement - I : Susceptibilities of paramagnetic and ferromagnetic substances increase with decrease in temperature.
Statement - II : Diamagnetism is a result of orbital motions of electrons developing magnetic moments opposite to the applied magnetic field.
Choose the correct answer from the options given below
- A
Both Statement - I and Statement - II are true.
- B
Both Statement - I and Statement - II are false.
- C
Statement - I is true but Statement - II is false.
- D
Statement- I is false but Statement - II is true.
JEE MAIN 2022 · 28 JUN S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The space inside a straight current carrying solenoid is filled with a magnetic material having magnetic susceptibility equal to 1.2×10−5. What is fractional increase in the magnetic field inside solenoid with respect to air as medium inside the solenoid?
- A
1.2×10−5
- B
1.2×10−3
- C
1.8×10−3
- D
2.4×10−5
JEE MAIN 2022 · 27 JUN S1Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The susceptibility of a paramagnetic material is 99. The permeability of the material in Wb/A - m, is
[Permeability of free space μ0=4π×10−7 Wb/A - m]
- A
4π×10−5
- B
4π×10−6
- C
4π×10−7
- D
4π×10−4
JEE MAIN 2022 · 24 JUN S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
The soft-iron is a suitable material for making an electromagnet. This is because soft-iron has
- A
low coercivity and high retentivity.
- B
low coercivity and low permeability.
- C
high permeability and low retentivity.
- D
high permeability and high retentivity.
JEE MAIN 2021 · 25 FEB S2Magnetisation, magnetic intensity, susceptibility and permeabilityTRANSCRIBED
In a ferromagnetic material, below the curie temperature, a domain is defined as:
- A
a macroscopic region with saturation magnetization.
- B
a macroscopic region with consecutive magnetic dipoles oriented in opposite direction.
- C
a macroscopic region with zero magnetization.
- D
a macroscopic region with randomly oriented magnetic dipoles.