In the determination of Young’s modulus by using Searle’s method,a wire of length L=2 mand diameter d=0.5 mmis used. For a load M= 2.5 kg, an extension l = 0.25 mm in the length of the wire is observed. Quantities d and/ are measured using a screw gauge and a micrometer, respectively. They have the same pitch of 0.5 mm. The number ofdivisions on their circular scale is 100. The contributions to the maximum probable error of the Y measurement
To determine Young's modulus using Searle's method, we use the formula:
Given:
Length of wire,
Diameter of wire,
Load,
Extension in length,
The quantities and are measured using a screw gauge and a micrometer, respectively, both having a pitch of 0.5 mm and 100 divisions on their circular scale. The least count, which is the smallest measurement that can be accurately read, is:
Hence, the least count, and , are both 0.005 mm.
Error in measurement of (extension length) is:
Error in measurement of (diameter) is:
Using the formula for Young's modulus, the combined error is:
The relative error in is given by:
As can be seen:
Therefore, the contributions to the error in the measurement of from errors in measuring and are the same.
Tagged Errors in measurement and significant figures. Machine-assigned, so read it as a strong shortlist rather than a verdict.