In a screw gauge, there are 100 divisions on the circular scale and the main scale moves by mm on a complete rotation of the circular scale. The zero of circular scale lies 6 divisions below the line of graduation when two studs are brought in contact with each other. When a wire is placed between the studs, 4 linear scale divisions are clearly visible while division the circular scale coincide with the reference line. The diameter of the wire is ______ mm.
A screw gauge has 100 circular scale divisions and a pitch of 0.5 mm, meaning the main scale moves 0.5 mm per complete rotation. The least count is mm.
Because the zero of the circular scale lies 6 divisions below the reference line, there is a positive zero error of mm.
When measuring the wire, the main scale reading is 4 divisions 0.5 mm = 2.00 mm, and the circular scale reading is 46 0.005 = 0.23 mm. Thus the observed reading is 2.00 + 0.23 = 2.23 mm, and the corrected reading is 2.23 - 0.03 = 2.20 mm, which can also be written as mm.
Hence, the diameter of the wire is mm.
Tagged Screw gauge: pitch, least count and zero error. Machine-assigned, so read it as a strong shortlist rather than a verdict.