A power transmission line feeds input power at 2300 V to a step down transformer with its primary windings having 4000 turns. The output power is delivered at 230 V by the transformer. If the current in the primary of the transformer is 5 A and its efficiency is 90%, the output current would be:
We have a power transmission line that supplies an input (primary) voltage of to a step-down transformer. The number of turns on the primary winding is given as . The transformer delivers an output (secondary) voltage of .
The current in the primary circuit is stated to be . The transformer works with an efficiency of . Our goal is to compute the secondary (output) current .
First, we recall the definition of efficiency for a transformer:
Here, is the input power and is the output power.
We now calculate the input power using the elementary electric power formula :
Substituting the given values,
Next, we find the output power from the efficiency relation. Rearranging the efficiency formula, we get
Putting the numbers in,
The transformer’s secondary voltage is already given as . Again using the power formula on the secondary side,
We solve for the unknown secondary current :
Substituting and , we obtain
Performing the division,
So, the secondary winding of the transformer delivers a current of .
Hence, the correct answer is Option D.
Tagged AC generator and transformer. Machine-assigned, so read it as a strong shortlist rather than a verdict.