For a series LCR circuit with , mH and pF connected across 220 V - 50 Hz AC supply, the phase angle between current and supplied voltage and the nature of the circuit is:
For a series LCR circuit, the inductive reactance is .
The capacitive reactance is .
Since , the net reactance is dominantly capacitive. The phase angle between the voltage and the current is given by . Here and , so , giving . The negative sign means the current leads the voltage by , which is characteristic of a predominantly capacitive circuit.
Therefore the phase angle between current and supplied voltage is and the circuit is predominantly capacitive.