RankRizz
JEE MAIN 2025 · 03 APR S2+4 / −1MEDIUMTRANSCRIBED

JEE Main 2025 Chemistry question — Titrimetric exercises

Compounds that should not be used as primary standards in titrimetric analysis are:
A. Na2Cr2O7Na_2Cr_2O_7
B. Oxalic acid
C. NaOH
D. FeSO4⋅6H2OFeSO_4 \cdot 6H_2O
E. Sodium tetraborate
Choose the most appropriate answer from the options given below:

SOLUTION

In titrimetric (volumetric) analysis a primary standard is the substance that is weighed accurately, dissolved, and its solution is used to standardise another reagent. For a compound to serve as a primary standard it must satisfy all the conditions below:
  • Very high purity and known formula
  • Stable in air (non-hygroscopic, non-deliquescent, does not react with CO2CO_2 or O2O_2)
  • Reasonably high molar/​equivalent mass (reduces weighing error)
  • Soluble in the chosen solvent and gives a stoichiometric reaction
  • Non-toxic and easily available

Let us test each compound given in the question against the above requirements.

Case A:

Na2Cr2O7Na_2Cr_2O_7 (sodium dichromate)
This salt is strongly hygroscopic and absorbs moisture from air, so its weighed mass does not give a fixed number of moles. Hence it fails the “stable in air” criterion and should not be used as a primary standard.

Case B:

Oxalic acid, generally used as the dihydrate H2C2O4⋅2H2OH_2C_2O_4\cdot 2H_2O, is available in high purity, has a fixed water of crystallisation, is not hygroscopic, and has a suitable equivalent mass. Therefore it is a good primary standard and is widely used for standardising KMnO4KMnO_4.

Case C:

NaOH (sodium hydroxide) readily absorbs both H2OH_2O (moisture) and CO2CO_2 from the atmosphere, forming Na2CO3Na_2CO_3. Because of this, its composition changes while weighing. Thus NaOH cannot be used as a primary standard.

Case D:

FeSO4⋅6H2OFeSO_4\cdot 6H_2O (ferrous sulphate hexahydrate) slowly oxidises to Fe3+Fe^{3+} in air and also effloresces (loses water). Hence its exact formula weight changes with time. It is therefore unsuitable as a primary standard.

Case E:

Sodium tetraborate (borax), Na2B4O7⋅10H2ONa_2B_4O_7\cdot 10H_2O, is available in very pure form, is not appreciably hygroscopic, and has a high equivalent mass. Because it meets all the criteria, it is an excellent primary standard for acid-base titrations.

Summarising the suitability:

• Not suitable →\rightarrow A (Na2Cr2O7Na_2Cr_2O_7), C (NaOH), D (FeSO4⋅6H2OFeSO_4\cdot 6H_2O)
• Suitable →\rightarrow B (oxalic acid), E (sodium tetraborate)

The compounds that should NOT be used as primary standards are therefore A, C and D only.